Lighting design is the discipline of planning and calculating the light in a space, natural and artificial: how much light is needed, from which luminaires, in what colour and without glare. For an interior designer a lighting scheme comes down to four moves: define the lighting scenes, choose the luminaires, check the result with a calculation (by hand, or with DIALux evo, which is free) and hand drawings and schedules to the electrician. One clarification that avoids a lot of confusion: the illuminance values in standards apply to workplaces, while for homes you work with good-practice values.
What lighting design is (and why interior designers need it)
Strictly speaking, lighting design is a branch of engineering that studies how light is produced, distributed and perceived. In practice it is the step that turns an idea ("I want a warm, cosy evening") into a list of luminaires, positions, wattages and controls that an electrician can build. Without it, light gets decided on site, when the holes are already cut in the ceiling and every change costs money.
Light is also what makes every other choice visible: pale oak under cold, flat light looks grey, and a textured plaster under raking light shows every shadow. That is why an interior designer cannot hand it over entirely. You need to be able to say what you want, in which rooms and with which scenes, and to read the calculation of whoever runs it. If you are after a guide for decorating your own home, with rooms, bulbs and budgets, this article takes a more professional angle.
The quantities to know: lumens, lux, candelas, kelvin, CRI and UGR
The vocabulary is short but has to be used precisely. The most common mix-up is between lumens and lux. Lumens tell you how much light a source emits; lux tells you how much of it lands on a surface. One lux is one lumen per square metre (in the US, footcandles are lumens per square foot; 1 footcandle is about 10.8 lux).
| Quantity | Unit | What it describes | What you use it for |
|---|---|---|---|
| Luminous flux | Lumen (lm) | The total amount of light emitted by a source or luminaire | Comparing bulbs and fixtures: watts say how much they consume, not how much they light |
| Luminous intensity | Candela (cd) | Light emitted in one specific direction | Telling whether a spotlight gives a narrow accent beam or a wide general one |
| Illuminance | Lux (lx) | Light reaching a surface, in lumens per square metre | Sizing the scheme: this is the value you calculate and verify |
| Luminance | cd/m² | The brightness of a surface as the eye sees it | Judging glare and contrast between walls, ceilings and luminaires |
| Colour temperature | Kelvin (K) | Whether the light looks warm (low values) or cool (high values) | Setting the mood: usually warm at home, more neutral in work zones |
| Colour rendering index | CRI or Ra, 0 to 100 | How faithfully the light shows the colours of objects | Stopping fabrics, wood and skin from changing colour under a poor source |
| Unified glare rating | UGR | The discomfort caused by luminaires (a CIE index) | Planning desks, tables and reading corners that don't strain the eyes |
A lower UGR means less glare, which is why workplace standards set a maximum value.
Two tips on method. First, when you compare two luminaires, look at the lumens and the type of light distribution, not the wattage. Second, decide the colour temperature room by room and keep it consistent within a room: lights of different tones in the same field of view are noticed at once and look untidy.
How much light each room needs
A distinction that online guides often skip. The European standard EN 12464-1 (2021 edition) covers the lighting of indoor workplaces. It sets maintained illuminance, uniformity, glare and colour rendering for offices, schools, shops and workshops. For an office, for example, writing, reading and data processing call for 500 lux maintained, with UGR no higher than 19 and Ra of at least 80. The value is "maintained" because it must hold for the whole life of the installation, allowing for ageing sources and dust. The standard also sets values for the area immediately around the task: it is the kind of detail that separates a design from a row of spotlights.
For homes, EN 12464-1 sets no values, because it is not a standard for dwellings. In practice designers use indicative values that vary a little from source to source. The ones below are ranges that recur in popular technical literature and manufacturers' guides: treat them as a starting point, not an obligation.
| Room or activity | Indicative illuminance | Design notes |
|---|---|---|
| Living room, general light | About 100 to 200 lx | Better to have low, dimmable general light plus task lights where needed |
| Bedroom, general light | About 100 to 150 lx | Reading in bed: about 200 to 500 lx from a dedicated light |
| Kitchen, worktop | About 300 to 500 lx | Put light under the wall cabinets so your body doesn't cast a shadow on the worktop |
| Bathroom, general light | About 100 to 200 lx | At the mirror you want about 300 to 400 lx with no shadows on the face |
| Study or home office (long sessions) | 500 lx | The value EN 12464-1 gives for office tasks |
| Office, writing and reading | 500 lx, UGR 19 or less, Ra 80 or more | EN 12464-1:2021, maintained illuminance |
Residential values are indicative, not prescriptive; the office value comes from EN 12464-1:2021. On a real project always check the standard's tables or the client's requirements.
How to set up a lighting scheme, step by step
A well-made lighting scheme follows a clear order. Skipping a step usually means redoing it on site.
- Brief and scenes. Habits come before fixtures: what happens in the room, at what time, with how many people. Scenes come from that, for example "dinner", "relax", "cleaning", "night". Each scene is a combination of circuits switched on and dimmed. You usually think in three layers: ambient light, task light and accent light.
- Choosing luminaires. For each function pick the type (recessed, pendant, track, wall light, LED strip), luminous flux, beam distribution, colour temperature and colour rendering. Check the shielding too: a spotlight that puts the source in the eyes of someone seated at the table is a glare error, not a matter of taste.
- Calculation. You check that the chosen luminaires produce the planned illuminance, with acceptable uniformity and no glare. You can do it by hand with the lumen method, or with software such as DIALux evo, which also calculates reflections between surfaces.
- Drawings and schedules for the electrician. A plan with the position and height of every light point, a legend with the product code of each luminaire, notes on circuits, controls and dimmers, and the data sheets attached. The electrical installation itself has to be designed and installed by a qualified professional under your local electrical code: you decide luminaires, scenes and positions, and they sign off the installation.
A worked example: a 20 m² living and dining room. The lumen method says the luminous flux to install equals the target illuminance multiplied by the floor area, divided by two loss factors: the utilisation factor (how much light actually reaches the working plane, depending on luminaire, geometry and surface colours) and the maintenance factor (ageing and dust). In software these values are calculated; here they are example assumptions.
| Item | Value | How you get it |
|---|---|---|
| Living room area | 20 m² (4 × 5 m, about 215 sq ft) | From the floor plan |
| Target average illuminance | 150 lx | Indicative value for general light, at table height |
| Useful flux needed | 3,000 lm | 150 lx × 20 m² |
| Assumed factors | Utilisation 0.5; maintenance 0.8 | Example assumptions: the calculation supplies them |
| Flux to install | About 7,500 lm | 3,000 lm ÷ (0.5 × 0.8) |
| Spotlights of about 800 lm each | About 10 light points | 7,500 lm ÷ 800 lm, rounded up |
If spotlights were the only source you would need about ten of them: in a real project part of the flux comes from pendants, wall lights and lamps, and the calculation checks the whole.
The result matters less than the reasoning. It shows you that 20 m² cannot be lit with four 400-lumen spotlights, and why it is usually better to spread the flux over many weaker, dimmable fixtures than over a few very powerful ones.
DIALux: what it is and how to use it for an interior
DIALux evo is a lighting calculation program widely used by designers and developed by DIAL GmbH. It lets you plan artificial lighting, daylight and emergency lighting, calculate values against standards (EN 12464-1 among them) and produce realistic ray-traced images. You can use it for a flat or for a whole building.
Is DIALux evo free, and what are the limits? For users it is free: it is funded by the luminaire manufacturers who are members, over 400 of them, and the free version includes the essential features and a catalogue of more than 2.5 million luminaires. The limit to know is this: in the free version you can only use products from member manufacturers. To use luminaires from other makers you need a DIALux Pro subscription or the Unlock Non-Members option. IFC import and export, the exchange with BIM models, also requires Pro, as does exporting data to Office. At the time of writing the current version is DIALux evo 14.1. It runs only on 64-bit Windows 10 and 11, with no Mac version.
The minimum workflow for a room. For a residential room the sequence is short, and it matches the software lessons in Module 2 of our Interior Design Master:
- Create the room. Import the DWG floor plan or draw the room at its real dimensions, ceiling height included. Then add doors and windows, because daylight comes in through them.
- Set materials and surfaces. The colour of walls, ceiling and floor changes the result, because light bounces. A dark floor with dark walls absorbs far more flux than a light room.
- Add furniture and obstacles. Sofas, tables and bookcases should be there at least as volumes: they block light and affect shadows.
- Choose and place luminaires. From the manufacturers' catalogues, according to the design. Start with general light, then add task and accent.
- Define scenes. For each scene you say which luminaires are on and at what dimming level.
- Calculate and read the results. Check average illuminance, uniformity, false colours (the map showing where light is too much or too little) and, where needed, glare. Then correct and recalculate.
- Generate the documentation. The software produces a document with luminaires, positions and results: attach it to the drawings for the electrician and the client.
A rule that holds for any calculation software: the result is only as reliable as the data you enter. If the photometric file of the luminaire is wrong, or you forgot a window, the numbers will look precise and mean nothing.
Lighting designer: who they are and when you need one
A lighting designer is the professional who deals specifically with a project's light: concept, choice of luminaires, calculations, installation details and fine-tuning on site. In most places the title is not tied to one compulsory licence, and training routes vary (university courses, master's programmes, courses run by industry bodies), so skill and portfolio are what count.
You need a lighting designer when light is central to the project or when its size justifies one: hotels, restaurants, shops, museums, large villas, facades. In a normal-sized home the interior designer usually sets up the lighting scheme, perhaps with a calculation check and the support of whoever designs the electrical installation. To see where one job ends and the other begins, remember that the interior designer defines scenes and chooses luminaires, while whoever signs off the installation guarantees that it complies with the rules.
Typical mistakes in a lighting scheme
- A single central light. It flattens the space and casts shadows on faces: you need at least two layers of light.
- Spotlights everywhere, all on together. A regular grid of recessed lights gives office lighting. Better to have distinct zones, each on its own circuit.
- No dimmer. Without control a room has one mood only. A dimmer costs little if planned from the start and a lot if added later.
- Different colour temperatures in the same room. As soon as one lamp has a different tone from the next, you notice.
- Ignoring daylight. An evening-only scheme that ignores the windows produces a dull room by day.
- Ignoring glare. Luminaires visible from where people sit or lie down need shielding.
- Deciding the light after the works. Holes and wiring are done once: the lighting scheme has to be defined before the installation goes in.
Frequently asked questions
How do you do a lighting calculation?
You start from the illuminance you want and the room size, estimate the luminous flux needed with the lumen method (illuminance times area, divided by the utilisation and maintenance factors) and then verify with software such as DIALux evo, which accounts for reflections, furniture and windows and returns average illuminance, uniformity and glare.
Who does the lighting design?
It depends on the job. The calculation and the lighting scheme can be done by an interior designer, an architect, an engineer or a lighting designer. The electrical installation that powers the luminaires has to be designed and installed by a qualified professional, in line with your local regulations.
What is a free lighting design program?
DIALux evo is free for users and runs on Windows. The limit is that the free version includes only luminaires from member manufacturers: to use other brands you need Pro or Unlock Non-Members.
How much does a lighting design cost?
There is no single price: it depends on floor area, number of rooms, level of detail (concept, calculations, construction drawings, site supervision) and the professional. The right way to find out is to ask for a quote after a site visit.
How many square metres do 2,000 lumens light?
It depends on the illuminance you want. In theory 2,000 lumens spread over 13 m² give about 150 lux. In practice part of the flux is lost (utilisation and maintenance factors): with the example values of 0.5 and 0.8, the same 2,000 lumens cover only about 5 m² at 150 lux.
Learning lighting design on the Master
Light is a skill you learn by doing, with a project in front of you. In the EULE Institute Interior Design Master, Module 1 devotes a chapter to lighting, from types of luminaire to the standard measures for adequate illumination, and Module 2 contains the DIALux evo lessons: from downloading the program to placing the floor plan, from door and window openings to arranging objects, then materials and photometric quantities, with a mentor who corrects your projects. There is a free Module 2 preview, so you can try the software before deciding. To build the foundations start from Module 1.